HAIFLF YEARLY |
ANNUALLY |
| Remove & clean filter |
1 |
Check all safety features provided in the machine |
1 |
Check all the bar nuts. |
| Check `O' ring of filter |
2 |
Check the machine for their correct functioning. |
2 |
Remove oil from the Main Tank & Prefill Tank. Clean both the tanks & Refill Oil. |
| Check Water cooling system for leakage |
3 |
Check the main relieve valve & Injection Valve |
3 |
Open the electric motor, grease it & reset it. |
| Check loose connections & tighten them, if any. |
4 |
Check Bolts fixed under head stock mould plate. |
4 |
Calibrate the pressure gauges, Temp.Controller, Thermocouple, Ammeter, Voltmeter, Timers. |
| Check the passage of injection unit. Lubricate & clean it. |
5 (a) (b) (c) (d) |
Check heater circuit Contamination Dirt. Loss in oil level. Clean oil cooler and change it. |
5 |
Check the main switches of the machine & cable also. |
| Check for oil leakage & rectify it. |
6 |
Check each zone individually |
|
|
| All oil tank covers should be fixed. |
7 |
Check tightness of the cover of the solenoid. |
|
|
| Check the gasket, if damaged then change it. |
8 |
Check the function of limit switches |
|
|
| |
9 |
Check hydraulic level |
|
|
| |
|
|
|
|
| |
|
Approved By |
|
|
| |
|